Fire Door Drop Test Inspection Form

A second test checks to make sure the automatic closing devices resets properly.
Fire door drop test inspection form. This course goes through the inspection process and the basics of repairing fire rated door assemblies. A written rolling fire door inspection report. Dates for 2008 include 7th may 26th june 25th september and 20th november. The drop test includes two steps.
This includes a comprehensive visual inspection and functional test ensuring that your fire doors are both. A fire door certification tag is attached to each tested fire door indicating the date the fire door was inspected tested and passed. Drop test a drop test is required to confirm that the fire door will close automatically during a fire emergency. This course will satisfy the nfpa 80 requirement for a knowledgeable person to conduct the inspections.
Fire door deficiencies identified during the pre drop test inspection should be corrected before the. Fire door deficiencies identified during the pre drop test inspection should be corrected before the drop test. Inspection inspect fire doors for damage to guides curtain and endlocks bottom bar hood and operating mechanism. Mark cummings is section head of fire testing at chiltern international fire.
This standard regulates the installation and maintenance of assemblies and devices used to protect openings in walls floors and ceilings against the spread of fire and smoke within into or out of buildings. Operational inspection open and close the door using normal operation. A 1 1 see annex k for general information about fire doors. Chiltern together with bm trada run timber fire doors explained training days which include a full scale fire door test demonstration.
Get and sign tds 271 rolling steel fire doors drop testing and dasma com form conditions that may affect the operation of the door. Any failure to pass this test may be immediately remedied through repairs. A first test checks to make sure your fire doors operate as they should and are providing full closure. Establish a contract with the door service provider regarding the cost of the inspection and drop test.
Drop test have a trained door systems technician perform an inspection and drop test of all fire door automatic closing features. Establish a contract with the door service provider regarding the cost of the inspection and drop test. A copy of your rolling fire door inspection and drop test results are kept in our company s records in case of an emergency or any compliance questions. 1 1 1 with the exception of fabric fire safety curtain assemblies this standard addresses assemblies that have.
The actual drop test. Have a trained door systems technician perform an inspection and drop test of all fire door automatic closing features. The nfpa 80 standard for fire doors mandates that overhead rolling steel fire doors be working properly and drop tested annually. Dasma recommends that the following procedures be observed.