Fire Exit Door Regulations Nz

The new fire and emergency new zealand act 2017 and the fire and emergency nz fire safety evacuation procedures and evacuation schemes regulations 2018 both describe.
Fire exit door regulations nz. Fire exit doors are the final door on an emergency exit route that must lead to a place of safety. Nz fire doors is a member of wganz doors working group. The nfpa emergency exit door requirements code states there is a maximum travel distance allowed to find an exit. Behind every fire door we manufacture is immense technical knowledge that helps you to get exactly the right fire doors for your project.
The new zealand building code nzbc includes requirements for fire doors in the acceptable solutions c as1 to c as6. Fire resistance ratings fire resistance. The current situation is that the existing egress provisions are unlikely to deliver the evacuation times required by fire safety designs. If there is a fire in the area where occupants are they are already being exposed to smoke fire and heat.
Keep exit route doors free of decorations or signs that obscure the visibility of exit route doors. Fire safety and evacuation of buildings regulations 2006. There is an approved document guidance available from the builders hardware industry federation bhif hardware for fire and escape doors. The acceptable solutions require fire doors to comply with nzs 4520 fire resistant door sets ref.
We work closely with specifiers and builders to ensure new zealand construction projects get the fire doors they need to satisfy regulations aesthetic considerations and budget constraints. Issue 4 2012 detailing the requirements for any fixtures and fittings used with fire doors and fire. The fire door manufacturers sub group addresses issues of interest and concern and publishes the industry consensus on the wganz fire doors pages. This access to exit requirements seeks to minimize occupants exposure to these and other hazards.
Click on the logo to find out more. An occupier in relation to a building includes any person lawfully entitled to be in the building for example a visitor. Exit doors must not be locked barred or blocked there can be a management system in place where doors need to be locked due to people being under care or supervision. Revoked on 1 july 2018 by regulation 36 of the fire and emergency new zealand fire safety evacuation procedures and evacuation schemes regulations 2018 li 2018 96.
Search within this legislative instrument. Suggested means of correcting this potentially serious shortfall in egress capacity go beyond the obvious solution of simply increasing exit widths which apart from new buildings would be considered. Post signs along the exit access indicating the direction of travel to the nearest exit and exit discharge if that direction is not immediately apparent. Fire doors are assigned a fire resistance rating frr from the results of fire testing to as1530 4.