Fire Smoke Damper Electrical Requirements

Fire smoke damper hvac fsd35 ruskin fsd35 1ul555 ul555s leakage class 3 classified.
Fire smoke damper electrical requirements. An important aspect of limiting the spread of fire smoke and toxic gases is protecting openings in fire and smoke rated assemblies that are provided to allow the building to be functional. Low pressure less than 3 w c. The actuator accepts a 0 to 10 v or 4 to. Out of wall fire and fire smoke damper iom true round fire and fire smoke damper iom electrical guidelines.
A combination fire and smoke damper looks very similar to a smoke damper but has a high temperature sensor to close the damper from heat along with the local smoke detector. The metal fab fire damper pressure rating as it relates to manufacturing the damper. Standard fire damper no additional construction is required. Section 9 3 1 smoke control systems shall be installed inspected tested and maintained per nfpa 92a.
This includes fire. Type c dampers and type c sleeved dampers are the only dampers that can be built as medium high or high pressure. Electrical input may be needed for products discussed within this iom. Fire damper required smoke damper required typically ducts shall not penetrate fire walls but if allowed then damper is required no requirements stated in section yes unless penetration meets astm e119 or ul 263 or meets all of the following.
Standard for smoke dampers. All wiring shall be done in accordance with the latest edition of the national electrical code ansi nfpa 70 any local. Section 9 2 1 hvac equipment and ductwork shall be in accordance with nfpa 90a. Wall is 1 hr or less building is fire sprinklered entire duct system is 26 ga.
Dampers are often used to protect openings for heating ventilation and air conditioning hvac ducts through these rated assemblies. The fsd35 is a combination fire and smoke damper designed with triple v groove blades and controlled closure technology that provides point of origin fire containment and operational flexibility in static and dynamic smoke management systems. Standard for fire dampers and ul555s. It also serves to interrupt migratory airflow resist the passage of flame and maintain the integrity of the fire rated separation.
Section 8 5 5 4 2 smoke dampers and combination fire smoke dampers shall be inspected tested and maintained per nfpa 105. For belimo combination fire smoke damper actuators intended for installation in accordance with national protection association standard for installation of air conditioning and ventilating systems nfpa 90a damper actuators must meet the construction and performance requirements in ul555.