Fire Sprinkler System Schematic Drawing

Engineered fire systems inc.
Fire sprinkler system schematic drawing. Sprinkler system design program. Sprinkler placement and spray patterns layouts of individual sprinkler zones stations valve and sprinkler pipe placement. A tree system is end feed that is water is only fed from one direction as opposed to a grid or loop system when water may arrive at the sprinkler head from more than one direction. Record it in the psi box.
The sprinkler system design capacity in gallons per minute gpm. Wet pipe sprinkler presentation. A sprinkler system is a good investment that will last for many years bringing both safety and peace of mind. Below is a diagram of the three sprinklers and three pipes which we will calculate.
Fire sprinkler systems control or put out 99 of fires in buildings where they are installed. Is a full service fire protection design and engineering company specializing in producing high quality fire sprinkler plans for any type of project. Working pressure will be used when choosing sprinkler heads and designing the system. Below are actual examples of our fire sprinkler drawings.
Otherwise known as an fdc or siamese connection since there are two inlets on the connection this connection is located on the exterior of the building. Set out construction sprinklers permit a reduction in the class finish requirements for walls or ceilings that. Losses from fires in buildings with sprinklers are estimated to be only one tenth of those in unprotected buildings. Below is a list of different parts that make up the anatomy of a sprinkler system.
Wet systems use automatic sprinkler heads attached to piping containing water and connected to a water supply. Detailed parts list for pvc or poly pipe systems. Different types of fire alarm system such as conventional addressable intelligent and smart wireless designs are used for the same purpose i e. In case of emergency the sounders will operate to warn the people around to evocative via general or emergency exit.
Record this number in the gpm box. 717 5 2 nfpa 13 and nfpa 13r. Fire dampers sprinklers eliminate the required fire dampers in ducts for hvac systems fire barrier walls that have a required fire resistance rating of 1 hour or less. Next locate your system s static pressure and move down that column and find the system s working pressure.
All of these drawings are saved in adobe pdf file format. Connection used by the fire department to pump water into the fire sprinkler or standpipe system to supplement the building s water supply. It can be a life saver. This is because no equipment other than the sprinkler heads are required to operate.
Step by step assembly instructions. Detailed color coded drawings with. 8 fire department connection.